Closed-Loop Alkaline Recycling
Proves an Award Winning Application
by Tim Keiper and John F. Russo
A Closed -loop chemical recycling system not only improved product
quality and lowered costs for a company-it won their team of engineers
an award. The six engineers of the "Stain Team," headed by
Tim Keiper of Instrument Specialties Company Inc (Delaware Water Gap,
Pa), earned the company's Continuous Improvement Pioneer Award after
reworking their cleaning operation to include an AquaChemical TM AC002012
recycling system from Separation Technologists, Inc. (Methuen, Mass).
One process conducted at Instrument Specialties is a degreasing operation,
where parts are cleaned prior to electroplating. The parts themselves
are beryllium copper strips used in shielding equipment for computers
and other electronic devices (figures 1 &2). The parts washer
runs at a temperature of 170 degrees F. The contaminants being removed
from the parts include water-soluble stamping oils, suspended solids,
and metal particles. Prior to implementing the new recycling system,
a coalescer and skimmer were the only oil removal methods used in the
operation.

The company used a chemical cleaner to remove oil from the parts. A
problem arose when small amounts of oil were detected on the parts after
cleaning, which led to quality issues. The team of engineers researched
and installed the Aqua-Chemical membrane-type, closed-loop chemical
recycling system to remove the contaminants and then concentrate them
for disposal.
The Stain Team expected to improve product quality, which was the initial
goal. But in achieving that goal, they realized significant other benefits
as well.
Prior to purchasing the recycling system, Instrument Specialties employed
a cleaning operation whereby 600 gallons of cleaning solution was changed
every two to three days; this was done in an effort to maintain quality.
Despite these efforts, spotting continued to be a substantial problem,
creating bare spots and poor adhesion. Indeed, it was the key cost factor
in postcleaning plating part failures.
The company paid a high cost for their inefficient cleaning system,
not only in terms of buying new chemicals, but in waste haulage and
disposal. And, even with all the changeover and expense, the desired
quality still wasn't being achieved.
Revamping the
Whole Process
The Stain Team began by working with Separation Technologists to examine
the full scope of the problem and find its cause. A pilot study was
conducted on the cleaning solution used in Instrument Specialties' operation.
Results suggested several problematic facets-not only in the chemistry,
but in the entire cleaning process.
Neither the coalescing nor the skimming mechanism was capable of removing
significant amounts of the emulsified oil from the cleaning system.
The oil could therefore redeposit on the parts. The research team determined
that installing the AquaChemical recycling system would solve this problem.
The emulsified oil could be easily removed by mechanical means- without
using special chemicals to achieve oil separation.
The Stain Team, in conjunction with Separation Technologists and a
new chemical supplier Matchless Metal Polish, developed an alternative
cleaning solution for use with their prospective recycling system. The
new chemistry, could be close-loop recycled to remove the free and emulsified
oil that lingers on parts after washing.
This new cleaning chemistry (Matchless Metal Polish, SC-114-L) is a
milky alkaline, highly wetted, liquid non-stretch soak cleaner that
is effective as both a soak and an ultrasonic cleaner. It effectively
removes oil and soil from aluminum, zinc die-castings, brass, and steel
without attack on the base metal and can be used in soak tanks, agitating
parts washing equipment, and ultrasonic units. It is compatible with
microfiltration and boasts a wide operating temperature range.
The new chemistry has very free rinsing properties and a high soil
tolerance. Its mild alkalinity also prevents parts from discoloring.
The new solution is more potent, resulting in better cleaning effectiveness,
and demonstrates a 35% reduction in comparable cost over the old chemistry.
Reaping the
Rewards
Currently, the concentration of the cleaner ranges from 2% to 5%, and
0.3 gallons of chemistry are added on a daily basis to makeup for chemistry
dragout and undesired membrane removal of some of the cleaning chemistry.
The membranes are cleaned every alternate day and have never been replaces
in nearly one year of operation. Reductions in chemistry use, physical
labor, waste disposal, and product rejects have led to an annual cost
savings of almost $120,000. The typical components of the waste stream
include water-soluble oil and suspended solids, which are hauled away
for disposal.
The changeover of cleaning material, which was every two to three days,
has become once every six to eight weeks. During changeovers, the 600
gallons of used cleaning solution is evaporated, and the concentrate
is hauled away along with the remaining waste oil. This considerable
extension in working time means tremendous savings in cleaning solution
costs, since each batch has eight times the working life of the old.
Similarly, haulage and disposal costs have been reduced proportionately,
as has system maintenance. With continuous recycling, alkaline chemical
spikes have been eliminated, resulting in a more consistent concentration
of chemistry.
The most significant achievement, of course, is the one first targeted
by the Stain Team: a total improvement in the quality of cleaning for
the finished product. "We are very close to a stain-free (defect-free)
product," stated Keiper. "The reduction of downtime in the
process has also helped in providing a benchmark of completely elimination
stains in all of our products."
New Technology
+ New Chemistry = Success
The key to the Stain Team's success lies largely with their implementation
of the AquaChemical technology and the Matchless Chemistry. The closed-loop,
membrane-type system has proven a valuable means of extending the working
life of the solution - and efficiently separating clean, usable solution
- well beyond the limits of previous technology. It has also simplified
the Instrument Specialties Company's operation.
"Holding tanks have been added to stop the time-consuming transfer
of used solution via drums, a time savings of approximately 75 percent,"
Keiper remarked. "The procedure is now automated, saving time and
eliminating the chance of spillage."
For more information about the AquaChemical system, or other closed-loop
wastewater treatment, recycling, and purification systems, contact Separation
Technologists Inc at (978) 794-1170, Fax (978) 794-0933. For more information
about the Matchless chemistry, contact the Matchless Metal Polish Company
at (800) 328-5436.
Reprinted from Parts Cleaning magazine May 1999
© 1999 Witter Publishing Corporation